# WICHTIG: VORHER MUSS DAS PROFIL AUF "FULL SPEED" gestellt werden
# damit die Automatik deaktiviert ist
# danach BMC reset durchführen!
# Lower Limit Alarm deaktivieren
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN1 lower 100 200 200
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN2 lower 100 200 200
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN3 lower 100 200 200
#ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN4 lower 100 200 200
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FANA lower 100 200 200
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN1 upper 9000 9000 9000
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN2 upper 9000 9000 9000
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN3 upper 9000 9000 9000
#ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FAN4 upper 9000 9000 9000
ipmitool -I lan -U ADMIN -P RXNISDHWQU -H 10.0.100.9 sensor thresh FANA upper 9000 9000 9000
# manuelle Lüfterdrehzahl setzen
# die letzten beiden Fehler sind THERMAL_ZONE und DUTY_CYCLE
# duty 0x00 -> ganz wenig
# duty 0x64 -> maximum
echo "setting fans to low - FAN1-FAN4"
ipmitool raw 0x30 0x70 0x66 0x01 0x00 0x15
echo "setting fans to low - FANA"
ipmitool raw 0x30 0x70 0x66 0x01 0x01 0x50
Drehzahl prüfen mit:
ipmitool sensor ; sensors